2: Operation Via the 8x8's Front Panel • 7
Version 2.0, February, 2007
If you have read the Introduction to Livewire; Sys-
tem Design Reference & Primer manual, you will know
that no each stream must have a unique channel number,
so don’t forget that now.
To program the node’s Transmit Base Channel fol-
low these steps:
Starting from the metering screen, press the <SE
-
LECT> button 5 times. The default TxBCH is
“00001”, so unless the unit has previously been pro
-
grammed, the display will show that entry.
Press and hold the <ID> button for 4 seconds. A
blinking cursor will appear below the first digit. Use
<SELECT> to change the digit indicated by the cur
-
sor (each press of this number will increment the dis
-
played digit by one).
Press the <ID> button to jump to the next digit. Use
<SELECT> to change the digit indicated by the cur-
sor. Continue until all digits of the TxBCH have been
entered.
Once the changes are complete, press the <ID> but-
ton repeatedly until no cursor is shown then press
<SELECT> to exit.
If you do not wish to save your changes do not press
<SELECT> after reaching the last digit. After ap
-
proximately 10 seconds the display will return to the
meter screen and the old settings will be restored.
Programming the unit’s Receive Base Channel
(RxBCH)
The Receive Base Channel is the number assigned to
the first of the eight streams to be received by this node
and output from its audio connectors. If the Receive Base
Channel is set to 00201 then the system will search the
Livewire network for eight streams on channel numbers
00201 through 00208. If a designated stream(s) is(are)
present the node will indicate this by illuminating the
lowest LED segment on the corresponding output meter.
Of course in many scenarios you will want to use non-
contiguous numbering for receive channels; these must
be assigned using the node’s web interface, see section 3
Advanced Programming.
1.
2.
3.
4.
5.
To program the node’s Receive Base Channel follow
these steps:
Starting from the metering screen, press the <SE
-
LECT> button 6 times. The default RxBCH is
“00001”, so unless the unit has previously been pro
-
grammed, the screen will show that entry.
Press and hold the <ID> button for 8 seconds. A
blinking cursor will appear below the first digit. Use
<SELECT> to change the digit indicated by the cur
-
sor (each press of this number will increment the dis
-
played digit by one).
Press the <ID> button to jump to the next digit. Use
<SELECT> to change the digit indicated by the cur
-
sor. Continue until all digits of the TxBCH have been
entered.
Once the changes are complete, press the <ID> but
-
ton repeatedly until no cursor is shown then press
<SELECT> to exit.
If you do not wish to save your changes do not press
<SELECT> after reaching the last digit. After ap
-
proximately 10 seconds the display will return to the
meter screen and the old settings will be restored.
1.
2.
3.
4.
5.
Comentários a estes Manuais