2: Operation Via the 8x8's Front Panel • 5
Version 2.0, February, 2007
Chapter Two:
Operation via the 8x8 node’s
front panel
Here we cover everything you need to know to cre-
ate a simple Livewire snake using only the unit’s front
panel.
Configuration & Testing
Basic configuration of the Livewire node can be per-
formed from the front panel. In addition, the system can
be configured over the network by using a web browser
accessing the node’s built in web server, see section 3
Advanced Programming.
Powering up
When the Livewire node is powered on, you should
observe the following: The 4 LED indicators should il
-
luminate briefly, and the LED meter display will display
a screen test. Next, you should see the node’s name dis
-
played (default name is “LiveIO”). After a brief period
of time, you will see the normal front panel bargraph
meter display (see section 1, above).
Restoring Defaults
To restore the Livewire node to the default settings
follow the steps below:
Power the node OFF.
Depress and hold the SELECT and ID buttons.
Power ON the unit while continuing to hold the
above buttons.
After about 8 seconds will see the word “RESET 3
S” displayed. If you release the buttons within 3 sec
-
onds no changes will occur. If you continue to hold
the buttons after 3 seconds the default settings will
be set and “REBOOT” will be displayed. At this time
release the SELECT and ID buttons.
1.
2.
3.
4.
Bench Testing
Two Livewire nodes may be connected together in
“Point to point” mode (e.g. Ethernet snake mode) to ver-
ify operation of the units. When connected in this way
the audio fed to “input 1” of “node A” will be output on
“output 1” of “node B” whereas the audio on “input 1” of
“node B” will be output on “output 1” of “node A”. Like-
wise, the other inputs for the two nodes will be mapped
correspondingly. To connect two units in “point to point”
fashion follows these steps:
Restore default settings on both of the Livewire nodes
to be connected. See “Restore Defaults”, above.
Enable streaming on each unit as follows: Press the
<SELECT> button repeatedly until MODE is dis-
played. Press and hold the <ID> button until a cur
-
sor appears under the current setting (e.g. Off). Press
<SELECT> repeatedly until SNAKE is displayed.
Press <ID> to confirm your entry.
Connect the two units using a “Crossover 10/100
Base-T” Category 6 cable 100 meters maximum (see
Introduction to Livewire; System Design Reference
& Primer).
The LINK and LIVEWIRE LEDs should illuminate
on both nodes. The MASTER LED should illuminate
on one unit and the SYNC LED should illuminate on
the other unit.
The eight receive (output) meters on each of the two
units should show the lowest segment illuminated to
indicate streams are being received.
Audio may now be fed into each input and will be re
-
cieved on the corresponding output of the other unit.
Basic Programming - via the front panel
Basic programming of the Livewire node can be
accomplished using the front panel display and the SE
-
LECT and ID buttons. The node’s name and other infor-
mation can also be checked from the front panel.
Programming the unit’s IP address
Each Livewire node must have a unique IP address.
The only exception is when two nodes are connected in
the point-to-point (snake) configuration.
1.
2.
3.
4.
5.
6.