2: Operation Via the 8x8's Front Panel • 6
Version 2.0, February, 2007
To program the node’s IP address follow these steps:
Starting from the metering screen, press the
<SELECT> button once. The default IP address is
“0.0.0.0”, so unless the unit has previously been pro-
grammed, the screen will show “000.000.000.000”.
Press and hold the <ID> button for 4 seconds. A
blinking cursor will appear below the first digit. Use
<SELECT> to change the digit indicated by the cur
-
sor (each press of this number will increment the dis
-
played digit by one).
Press the <ID> button to jump to the next digit. Use
<SELECT> to change the digit indicated by the cur
-
sor. Continue until all digits of the IP address have
been entered.
Once the changes are complete, press the <ID> but
-
ton repeatedly until no cursor is shown then press
<SELECT> to exit.
If you do not wish to save your changes do not press
<SELECT> after reaching the last digit. After ap-
proximately 10 seconds the display will return to
the meter screen and the previous settings will be
restored.
Checking the Livewire Node Name
With the meter screen displayed, press SELECT
twice. The name of this Livewire node will be displayed.
The default is LiveIO. To change the name of a node you
must use the Browser interface, see section 3 Advanced
Programming.
Checking the Livewire Node Software Version
With the meter screen displayed, press SELECT three
times. The software version will be will be displayed.
Programming the Node’s Streaming Mode
The streaming mode can be selected from the front
panel. The default mode is to have streaming disabled
(e.g. OFF), thereby allowing safe connection to a com
-
puter or LAN for programming. See the Introduction to
Livewire; System Design Reference & Primer manual
for more on streaming. The possible settings for stream
-
ing mode are shown here:
1.
2.
3.
4.
5.
OFF This disables both streaming of Livewire au
-
dio and Livewire clock packets. This setting is useful
when you wish to connect the unit to a non-Livewire
-
LAN or directly to a computer to configure the IP
address and other settings.
FAST This enables Fast Stream generation and
also permits clock packet generation. This is the
typical setting for most Livewire audio network ap-
plications.
SLOW This enables Slow Stream generation as
well as Livewire clock packets. This is the usually
setting for a Axia node used in conjunction with a
computer or other device where delay is unimport
-
ant.
SNAKE The mode is appropriate for when two
Axia nodes are directly connected with a null Eth
-
ernet cable. This enables Livestreams and Livewire
clock packets only. SNAKE mode differs from fast
by disallowing local loopback capability in the node.
CUSTOM – This indicates that the Streaming Mode
parameters have been configured using the unit’s
web page interface.
To change the Streaming Mode from the front panel
follow these steps:
Press the <SELECT> button repeatedly until MODE
is displayed.
Press and hold the <ID> button until a cursor appears
under the current setting.
Press <SELECT> repeatedly until SNAKE is dis
-
played.
Press <ID> to confirm your entry.
Programming the units Transmit Base Channel
(TxBCH)
The Transmit Base Channel is the number assigned
to the first of the eight streams to be transmitted by this
unit. If the Transmit Base Channel is set to 00101 then
the system’s eight streams would be on channel numbers
101 through 108. Non-contiguous numbering is possible,
however in that case they must be assigned using the
node’s browser user interface, see section 3 Advanced
Programming.
1.
2.
3.
4.